Description
Geotech Portable CO2 Gas Analyser Imported Model G100
Geotech Portable CO2 Gas Analyser Imported Model G100 is a CO2 & O2 monitoring or calibration device. Geotech Analyser has been used successfully in the market for decades and till date we have not received any serious complaint about the product. The IVF Lab CO2 Incubator Gas Analyzer is used to test the CO2 of incubators in the IVF lab or it may also use to check carbon dioxide of any kinds of close chamber.
This analyzer is used in the research and pharmaceutical industries to test and calibrate CO2 incubators. This analyzer is extremely accurate. It comes in two kinds of different model: G100 CO2 and G100 CO2 + O2 analyzer geotech. This is the world’s best IVF Lab CO2 Incubator Gas Analyser till date.
Geotech Portable CO2 Gas Analyser Imported Model: G100
Technical Specification
| POWER SUPPLY | |
| Battery type | Li Ion |
| Battery life | 12 hours (10 hours with pump)* |
| Battery lifetime | 600 cycles* |
| Battery charger | 5Vdc external power supply and internal charging circuit |
| Charge time | 4 hours (App.) |
| Alternative power | 5Vdc power supply |
| GAS RANGES | |
| Gases measured | CO2 (By custom dual wavelength infra-red with reference channel) |
| O2 (optional)
(By internal electrochemical cell) |
|
| Oxygen cell lifetime | Approximately 3 years in air |
| Range | CO2 – 0-20% |
| O2 (Optional) – 0-100% | |
| Typical accuracy* | CO2 – ± 1% of range after calibration |
| O2 – ± 1% of range after calibration | |
| Response time T90 | CO2 – ≤ 20 seconds |
| O2 – ≤ 60 seconds | |
| *Typical accuracies | All typical accuracies quoted are after calibration plus accuracy of calibration gas used. |
| FACILITIES | |
| Temperature (optional) | x 2 using optional probes 0°C to +50°C |
| Temperature accuracy, typical | ± 0.1°C from 32 to 44°C, ± 0.2°C over the rest of the range |
| Barometric pressure | 800 – 1200 mbar* |
| RH measurement (optional) | RH Probe 0-100% RH non condensing |
| RH accuracy | ± 1.5% RH across the range |
| Visual and audible alarm | User selectable CO2 and O2 alarm levels |
| Communications | USB type B mini-connector, HID device class |
| Data storage | 1000 reading sets + 270 events |
| PUMP | |
| Flow | 100cc / min typically |
| ENVIRONMENTAL CONDITIONS | |
| Operating temperature | 0°C to 50°C |
| Relative humidity | 0- 95% non condensing (RH probe 0- 100% non condensing) |
| Barometric pressure | ± 500mbar from calibration pressure |
| IP rating | IP40 |
TECHNICAL SPECIFICATIONS CONTINUED
| PHYSICAL | |
| Weight | 495 grams (app.) |
| Size | L 165mm, W 100mm, D 55mm |
| Case material | ABS / polypropylene with silicone rubber inserts |
| Keys | 17 resin capped silicone rubber keys |
| Display | Liquid crystal display, 128 x 64 pixel With RGB LED back-light |
| Gas sample filters | Built-in gas dryer tube to remove moisture User replaceable PTFE water trap filter |
| CERTIFICATION | |
| EN 50270:2006 | Electromagnetic compatibility – electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
| EN61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 1: General requirements |
| ISO17025 | Calibration to UKAS certificate number 4533 |
Technical Specification
| POWER SUPPLY | |
| Battery type | Li Ion |
| Battery life | 12 hours (10 hours with pump)* |
| Battery lifetime | 600 cycles* |
| Battery charger | 5Vdc external power supply and internal charging circuit |
| Charge time | 4 hours* |
| Alternative power | 5Vdc power supply* |
| GAS RANGES | |
|
Gases measured |
CO2
(By custom dual wavelength infra-red cell with reference channel) |
| O2 (optional)
(By internal electrochemical cell) |
|
| Oxygen cell lifetime | Approximately 3 years in air |
|
Range |
CO2 – 0 – 20% |
| O2 – 0 – 100% | |
|
Typical accuracy* |
CO2 – ± 1% of range after calibration |
| O2 – ± 1% of range after calibration | |
|
Response time, T90 |
CO2 – ≤ 20 seconds |
| O2 – ≤ 60 seconds | |
| *Typical accuracies | All typical accuracies quoted are after calibration plus accuracy of calibration gas used. |
| FACILITIES | |
| Temperature (optional) | x2 using optional probes, range 0°C to +50°C |
| Temperature accuracy | ± 0.2°C |
| Barometric pressure | 800- 1200 mbar |
| RH measurement (optional) | RH Probe 0 – 100% RH non condensing |
| RH accuracy | ± 1.5% RH across the range |
| Visual and audible alarms | User selectable CO2 and O2 alarm levels |
| Communications | USB type B mini-connector, HID device class |
| Data storage | 1000 reading sets + 270 events |
| PUMP | |
| Flow | 100cc / min typically |
| ENVIRONMENTAL CONDITIONS OF GEOTECH PORTABLE CO2 GAS ANALYSER IMPORTED | |
| Operating temperature | 0°C to 50°C |
| Relative humidity | 0 – 95% non-condensing |
| Barometric pressure | ± 500 mbar from calibration pressure |
| IP rating | IP40 |
| PHYSICAL | |
| Weight | 495 grams |
| Size | L: 165mm, W: 100mm, D: 55mm |
| Case material | ABS / Polypropylene with Silicone Rubber inserts |
| Keys | 17 Resin capped silicone rubber keys |
|
Display |
Liquid crystal display, 128 x 64 pixels |
| With RGB LED back-light | |
|
Gas sample filters |
Built-in gas dryer tube to remove moisture |
| User replaceable PTFE water trap filter in Geotech Analyser | |
| CERTIFICATION OF GEOTECH PORTABLE CO2 GAS ANALYSER IMPORTED | |
| EN 50270 : 2006 | Electromagnetic compatibility- Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
| EN 61010-1 : 2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 1: General requirements |
Our other Similar Product:-